ThinkChat2.0新版上线,更智能更精彩,支持会话、画图、阅读、搜索等,送10W Token,即刻开启你的AI之旅 广告
<!-- toc --> ![Product Image][1] ## 1 Technical Specification ### 1.1 Feature - Measure multiple parameters of single-phase AC equipment, such as voltage, current, power, etc. - Apply the dedicated measuring chip with high precision - Support wireless 802.11 b/g/n protocol - 1 RS-485 port - Support standard MODBUS-RTU, good compatibility and easy programming - ESD Protection - Wide operating voltage AC80~265V, - Reverse connection protection - High isolation voltage, DC2000V withstand voltage ### 1.2 Technical parameters #### 1.2.1 Single-phase AC input - Voltage Range: 100V, 220V - Current Range: 5A、50A、100A - Signal Processing: applies dedicated measuring chip, 24bit AD sample - Overload Capacity: Not damaged under 5 times current, 1.2 times voltage within 20mS - Input Impedance: Voltage channel>1 kΩ/V;Current Channel≤100mΩ #### 1.2.2 Communication interface - Interface:RS-485 - Protocol:MODBUS-RTU; - Data format:“n,8,1”; - Baud rate:1200、2400、4800、9600Bps;9600Bps by default; #### 1.2.3 Data Output - Voltage, Current, Power, Energy, Power Factor, Frequency #### 1.2.4 Precision - Voltage、Current、Energy:±1.0%; - Active Power: Class 1 #### 1.2.5 Isolation - Isolation Voltage: 2000VDC; - Communication port is isolated with power input port #### 1.2.6 AC Input - Voltage Range: 100V-220V - Current Range: 5A-100A - Peak voltage: not exceeds 265V; - Typical power consumption:≤2W;(220VAC input) #### 1.2.7 Work Environment - Working Temperature: -20~+70℃;Storage Temperature:-40~+85℃; - Absolute Humidity:5~95%; - Altitude:0~3000m; #### 1.2.8 Temperature Drift - Temperature Drift≤100ppm/℃; #### 1.2.9 Product Size - Product Size: 90×36.5×58mm #### 1.2.10 W-Fi Parameters - UART baud rate:9600/8/n/1 - Support WiFi 802.11b/g/n, Wi-Fi frequency 1-13 - Wi-Fi transmit power: 18.5dBm@11b,15.5dBm@11g,14.5dBm@11n; - Wi-Fi frequency: 2.400~2.472GHZ - Highest transmit speed: 3686400bps - Support WiFi-DuSL Mode; - Maximum connections:8 - Support WEB; - Embedded PCB Antenna, support IPEX external antenna ## 3 C/T Dimensions The dimension of CT is shown as figure3(Unit: mm) ![][2] ## 4 Terminals - Wire the electricity wire connect to terminal UL(Live)and UN(Neutral) for voltage measurement; - The live wire must go through the hole of C/T (according to the current direction marked at the bottom of C/T ) - RS-485 interface has two terminals, terminal A is positive,B is negative; ##4 Indicator There are three indicators in the front panel,”RUN”, “REV” and “WiFi”; - RUN:Always on after powering on,flashing while the WiFi module is communicating with the power meter; - REV:Always on when the current is reversed - WIFI:Always on after the Wi-Fi module is connected to the router [1]:http://leweidoc.oss-cn-hangzhou.aliyuncs.com/lewei50/img/imeter-lewei50-20180116-1.jpg [2]:http://leweidoc.oss-cn-hangzhou.aliyuncs.com/lewei50/img/imeter-lewei50-20180116-2.jpg