## PLC下发失败错误码
~~~
case 6: ("the CPU does not support reading a bit block of length")
case 10: ("the desired item is not available in the PLC")
case 3: ("the desired item is not available in the PLC (200 family)")
case 5: ("the desired address is beyond limit for this PLC")
case -124: ("the PLC returned a packet with no result data")
case -125: ("the PLC returned an error code not understood by this library")
case -126: ("this result contains no data")
case -127: ("cannot work with an undefined result set")
case -128: ("Unexpected function code in answer")
case -129: ("PLC responds with an unknown data type")
case -123: ("cannot evaluate the received PDU")
case 7: ("Write data size error")
case 1: ("No data from I/O module")
case -1024: ("Short packet from PLC")
case -1025: ("Timeout when waiting for PLC response")
case -130: ("No buffer provided")
case -131: ("Function not supported for S5")
case -20: ("Serial read error")
case -21: ("can't a 0xE5 response")
case -22: ("do not write completely")
case -23: ("Data type unsuport")
case -24: ("unknown data type,please check the ppi table")
case -25: ("data lenth of written is beyond the limition")
case -26: ("PLC return format error of read")
case -27: ("PLC return format error of write")
case -28: ("return data lenth of read is beyond the limition")
case 0x8000: ("function already occupied.")
case 0x8001: ("not allowed in current operating status.")
case 0x8101: ("hardware fault.")
case 0x8103: ("object access not allowed.")
case 0x8104: ("context is not supported. Step7 says:Function not implemented or error in telgram.")
case 0x8105: ("invalid address.")
case 0x8106: ("data type not supported.")
case 0x8107: ("data type not consistent.")
case 0x810A: ("object does not exist.")
case 0x8301: ("insufficient CPU memory ?")
case 0x8402: ("CPU already in RUN or already in STOP ?")
case 0x8404: ("severe error ?")
case 0x8500: ("incorrect PDU size.")
case 0x8702: ("address invalid.")
case 0xd002: ("Step7:variant of command is illegal.")
case 0xd004: ("Step7:status for this command is illegal.")
case 0xd0A1: ("Step7:function is not allowed in the current protection level.")
case 0xd201: ("block name syntax error.")
case 0xd202: ("syntax error function parameter.")
case 0xd203: ("syntax error block type.")
case 0xd204: ("no linked block in storage medium.")
case 0xd205: ("object already exists.")
case 0xd206: ("object already exists.")
case 0xd207: ("block exists in EPROM.")
case 0xd209: ("block does not exist/could not be found.")
case 0xd20e: ("no block present.")
case 0xd210: ("block number too big.")
case 0xd240: ("Coordination rules were violated.")
case 0xd241: ("Operation not permitted in current protection level.")
case 0xd242: ("protection violation while processing F-blocks. F-blocks can only be processed after password input.")
case 0xd401: ("invalid SZL ID.")
case 0xd402: ("invalid SZL index.")
case 0xd406: ("diagnosis: info not available.")
case 0xd409: ("diagnosis: DP error.")
case 0xdc01: ("invalid BCD code or Invalid time format")
case -201: ("Start PLC faild")
case -202: ("Stop PLC faild")
case -203: ("Online read bytes error")
case -204: ("Online write bytes error")
case -205: ("Online write bits error")
case -1 : ("string to number error")
case -2 : ("formula calculation error")
case -3 : ("number type conversion error")
case -4 : ("number to byte error")
case -5 : ("number type unmatch")
case -6 : ("modbus send error")
case -7 : ("number type matching failed")
case -8 : ("value is illegle")
case -10 : ("name matching failed")
case 302 : ("不合法数值(如10进制格式中有16进制数字)")
case 303 : ("禁止写入(PLC使用ROM PACK)")
case 304 : ("不合法之命令格式(含不合法之命令码),或通讯命令无法执行")
case 305 : ("不能激活(下RUN命令但Ladder Checksum 不合)")
case 306 : ("不能激活(下RUN命令但PLC ID != Ladder ID)")
case 307 : ("不能激活(下RUN命令但程序语法错误)")
case 309 : ("不能激活(下RUN命令,但Ladder之程序指令PLC无法执行)")
case 310 : ("不合法之地址")
case 327 : ("LRC CHK ERROR OR COMMUNICATION COMMAND FORMAT INVALID")
case 322 : ("DEVICE ADDRESS INVALID")
case 323 : ("要求的资料超过范围")
case 321 : ("COMMAND CODE INVALID")
default: ("no message defined")
~~~
- 文档目录
- 智能网关使用说明
- P411硬件使用手册
- P42x硬件使用手册
- P43x硬件使用手册
- P45x硬件使用手册
- EdgeLink软件使用说明
- 智能网关功能说明
- 智能网关远程管理
- 防火墙功能使用说明
- GPS定位功能使用说明
- 本地固件升级
- TCP透传功能使用说明
- 工业云平台使用说明
- 旧组态功能使用说明
- 新组态功能使用说明
- V P N服务
- 云平台报警功能介绍
- 定时任务功能使用说明
- 视频监控功能使用说明
- 定时任务实现网关防拆功能
- 微信小程序使用说明
- 组织管理功能使用说明
- 新平台数据点表公式说明
- 旧平台数据点表公式说明
- 大屏监控使用说明
- 基本操作
- 1.新建大屏
- 2.画布介绍
- 3.添加组件
- 4.调整组件的图层和位置
- 5.预览、保存组件
- 6.修改大屏
- 组件使用说明
- 1.背景设置
- 2.图表类组件
- 2.1柱图形组件
- 2.2折线图组件
- 2.3饼图组件
- 2.4环形图组件
- 2.5象形图组件
- 2.6雷达图组件
- 2.7散点图组件
- 2.8漏斗图组件
- 3.文本类组件
- 3.1文本框组件
- 3.2跑马灯组件
- 3.3超链接组件
- 3.4实时时间组件
- 4.图片类组件
- 4.1图片组件
- 4.2图片框组件
- 4.3轮播图组件
- 4.4滑动组件
- 4.5iframe组件
- 4.6video组件
- 5.指标类组件
- 5.1翻牌器组件
- 5.2仪盘表组件
- 5.3字符云组件
- 5.4进度条组件
- 6.表格类组件
- 6.1表格组件
- 6.2选项卡组件
- 7.地图类组件
- 7.1地图组件
- 8.万能组件
- 8.1堆叠条形图
- 8.2正负条形图
- 8.3双向对比柱形图
- 8.4圆形柱形图
- 8.5嵌套饼图
- 8.6矩形树图
- 8.7K线图
- 组件数据
- 智能网关与电脑主机驱动列表
- ModbusRTU主站
- ModbusSlave软件模拟ModbusRTU从站
- MCGS触摸屏做ModbusRTU从站
- 威纶通触摸屏做ModbusRTU从站
- 西门子S7-200 Smart ModbusRTU从站
- 艾莫迅PLC做ModbusRTU从站
- 亚控组态王做ModbusRTU从站
- 海为PLC做ModbusRTU从站
- 英威腾PLC ModbusRTU从站
- ModbusTCP主站
- ModbusSlave软件模拟ModbusTCP从站
- MCGS触摸屏做ModbusTCP从站
- 威纶通触摸屏做ModbusTCP从站
- 西门子S7-200 Smart ModbusTCP数据采集
- 亚控组态王做ModbusTCP从站
- 创恒P700 DCS做Modbus TCP从站
- PLC自有协议主站
- 西门子S7-200 PPI
- 西门子S7-200 Smart以太网
- 西门子S7-1200 以太网
- 三菱FX协议
- 台达
- 永宏
- 信捷XC
- ModbusRTU从站
- ModbusPoll软件模拟ModbusRTU主站
- MCGS触摸屏做ModbusRTU主站
- 威纶通触摸屏做ModbusRTU主站
- 亚控组态王做ModbusRTU主站
- ModbusTCP从站
- ModbusPoll软件模拟ModbusTCP主站
- MCGS触摸屏做ModbusTCP主站
- 威纶通触摸屏做ModbusTCP主站
- 亚控组态王做ModbusTCP主站
- 智能网关串口透传
- 三菱PLC远程上下载
- 英威腾PLC远程上下载
- 台达PLC远程上下载
- 永宏PLC远程上下载
- 信捷PLC远程上下载
- 海为PLC远程上下载
- HighLink软件使用说明
- P401/P200系列DTU模块使用说明
- P401使用说明书(图)
- DTU配置工具使用说明
- 固件升级说明
- 串口透传:组态王与西门子S7-200远程采集
- P401应用西门子200远程数据采集
- V P N应用:网口远程上下载调试
- 西门子S7-200 SMART远程上下载调试
- 西门子S7-1200远程上下载调试
- 威纶通触摸屏远程上下载调试
- 昆仑通态触摸屏远程上下载调试
- HighLink方案远程调试功能说明
- 同时连接不同网关下的网络设备
- 第三方平台数据接入
- 网关接入阿里云物联网平台
- 网关接入客户自建MQTT服务器
- MQTT客户端接入创恒云平台
- 附录I、错误码说明
- 附录II、获取网关ID和设备ID
- HTTP API实现数据上报下发(新平台)
- HTTP API实现数据上报下发(旧平台)
- 网关接入华云RomaConnect云平台
- 创恒云点表导出至华为云
- 常见问题
- 设备状态显示离线
- HighLink常见问题
- 232/485串口通信连接不上
- VPN远程 常见问题 排查方法
- 数据采集常见问题
- 点表编写常见问题
- DTU配置工具常见问题
- 本地无法进入网关管理页面
- HighLink路由表常见问题
- AP和STA是什么意思
- 资料分享
- 常用MQTT客户端介绍及使用
- Modbus协议
- LTE-CAT1介绍
- 物联网卡问题总结
- 新老平台差别说明
- 联系我们
- 硬件定制开发
- 云平台定制
- 应用案例